Phenolic Grating

Home » Products » Phenolic Grating

Phenolic Grating

Share This Product:
Facebook
Twitter
LinkedIn

description

The USCG phenolic grating refers to the grille that has passed the U.S. Coast Guard Level 2 test (L2 Tests, L2 Tests contains the characteristics required by L3 Tests). This kind of grating uses phenolic resin with excellent performance and is made through a more rigorous process. It has high strength, high flame retardation, low smoke density, low toxicity, light weight, non-slip surface, maintenance-free, and UV resistance. , Impact resistance, corrosion resistance and aging resistance. The default color is the original color of resin: reddish brown.

The US Coast Guard has determined that such gratings can be used in the following places: offshore oil platforms, pedestrian passages, ship decks, subways, coal mines and other emergency escape routes or life-saving places.

Sino Composite offers with USCG certificated phenolic grating with both Molded and Pultruded grating.

F3059-24: Standard Specification for Fiber‑Reinforced Polymer (FRP) Gratings Used in Marine Construction and Shipbuilding.

This 2024 revised edition supersedes F3059‑18. It specifies test methods and acceptance criteria for FRP gratings for marine pedestrian platforms, with a rated pedestrian load of 4.5 kN/m² (94 lbf/ft²). It covers mechanical strength, anti‑slip, salt spray, UV weathering, flame spread and smoke toxicity. Note that it is for pedestrian service only and does not replace classification society rules such as ABS, DNV.

TEST REQUIREMENTS

ASTM F3059-24 Section 8Serviceability and Assembled Grating Flexural Strength 
ASTM F3059-24 Section 9 
ASTM F3059-24 Section 10Wheel Loading 
ASTM F3059-24 Section 11Impact Resistance 
ASTM F3059-24 Section 12Skid ResistanceASTM D2047-25
ASTM F3059-24 Section 13DurabilityASTM D4060-25
ASTM F3059-24 Section 14UV ResistanceASTM D4329-21 Cycle A
ASTM F3059-24 Section 15Saltwater Spray TestASTM B117-19
 Surface FlammabilityTest Method E84
 Structural Fire Integrity, F3059 L2 

Grating Specification

ItemSpecificationOpen  areaHeight(mm)Bar width (top&bottom mm)Specification Diagram
Phenolic Pultruded GratingPHP6038 60%3815/15
 PHP5038 50%3815/15
 PHP4038 50%3815/15

Phenolic Grating Photos